What is the function of an auto
terminating connector?
|
|
The function of an auto terminating connector is to create an internal termination (resistave load) when there is no mating connector attached. When mating connectors are attached the resistor is disengaged and a transmission path is created. This eliminates the need to attach terminators (dummy loads) to unconnected ports. |